Solar Heat Collector |
This specially designed solar
glass, coated metal and insulated box, creates heat to
over 100 degrees Celsius. Air circulates through
the angled baffles picking up this heat and the returning
air is up to 50 degrees Celsius. There may be one
or two of these in your system. |
Width: 1520mm
Depth: 1220mm
Height: 120mm
Weight: 60kg |
PV Panel
|
Generates electricity from
the sun hitting the silicone crystal cells. They
typically last around 25-30 years. |
Power: 30 Watts
Voltage: 12 Volts
Current: 1.78Amps
Width: 592mm
Depth: 502mm
Height: 50mm |
Air flow control box |
Controls the direction air
travels. Through the collector and back to the house
in heating mode, and out to the exhaust flue in cooling
mode. |
Width: 500mm
Depth: 350mm
Height: 200mm |
Fan box |
Contains 4 powerful and reliable
fans with smart design features to give maximum air flow
and pressure. The fans are powered by the PV panel. |
Fans: 4 x 6.8 Watt Fans
Width: 500mm
Depth: 300mm
Height: 200mm
Air Flow Rate: 6m3/min
Inlet & Outlet Dia: 150mm |
Electronic control system |
User friendly control panel
sits in front of a sophisticated electronic control system
to manage the Sun Lizards operation. |
Wall mount switch & Cable
Functions: On/off, High, Low
240/12V plug pack |
Exhaust Flue or Adaptor
|
To get rid of unwanted hot
air in summer. The Exhaust Flue is suitable for roof cavities
while the Exhaust Adaptor is suitable for roofs with no
cavities. |
|
Ceiling Diffuser
|
Inlet or return air always
goes through the ceiling diffuser and out to the Sun Lizard |
Colours: White Only
Diameter: 150mm
Overall Width: 270mm |
Insulated Flex Duct
|
Insulated ducting for moving
the air from the building, to the Sun Lizard and back again |
Diameter: 150mm
Length: 6m
R-Value: 1 |
Y Branch
|
To allow the second solar collector
to be connected to the first solar heat collector |
Inlet opening: 150mm Diameter
Outlet Openings 150mm Diameter |
Dektites
Metal Roofs
Tiled Roofs
|
To allow for flashing of metal
pipe so to protect the roof from water or moisture. |
Pipe: 110mm – 170mm Diameter
Base: 284mm x 284mm (Metal) 600mm x 450mm (Tiled)
Colour: Black |
Gal Pipe
|
For external roof ducting,
connecting the Sun Lizard to the inlet and outlet vents. |
Pipe: 150mm Diameter |
Metal Bends
|
For external roof ducting,
connecting the Sun Lizard to the inlet and outlet vents. |
Pipe: 150mm Diameter |
Filtered Cooling Vent
|
Allow cool, filtered air to
come into the building during summer and can be sealed
off in winter. Comes with filter, floor register and floor
boot. Floor register comes in various colours. |
Width: 300mm
Depth: 100mm
Height: 135mm |
2NSCC Kit
(For Dual Collector System Only) |
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings with ceiling
cavity & pitched roofs facing:
- South or
- East and West (Collector on roof) |
2 x NS Roof Frames |
2EWCC Kit
(For Dual Collector System Only) |
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings with ceiling
cavity & pitched roofs facing:
- East only or
- West only |
2 x EW Roof Frames
2 x NS Roof Frames |
2NSNC Kit
(For Dual Collector System Only) |
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings with no a ceiling
cavity & a roof that is:
-Flat
- South Facing
- North Facing
- East & West Facing with a collector on each roof |
1 x Exhaust Adaptor
1 x Dektite removed
2 x NS Roof frames
(External insulated roof duct not included) |
2EWNC Kit
(For Dual Collector System Only)
|
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings without a ceiling
cavity & a roofs that is:
- East Facing only
- West Facing only |
1 x Exhaust Adaptor
1 x Dektite removed
2 x EW Roof frames
2 x NS Roof frames
(External insulated roof duct not included) |
1NSCC
(For Single Collector System Only) |
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings with ceiling
cavity & pitched roofs facing:
- South |
1 x NS Roof Frames |
1EWCC
(For Single Collector System Only) |
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings with ceiling
cavity & pitched roofs facing:
- East only or
- West only |
1 x EW Roof Frames
1 x NS Roof Frames
(Wall duct not incl.) |
1NSNC
(For Single Collector System Only) |
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings with no a ceiling
cavity & a roof that is:
-Flat
- South Facing
- North Facing |
1 x Exhaust Adaptor
1 x Dektite removed
1 x NS Roof frames
(Wall duct and external insulated roof duct not incl.) |
1EWNC
(For Single Collector System Only)
|
To tilt Heat Collectors at
optimum solar angle. Suitable for buildings without a ceiling
cavity & a roofs that is:
- East Facing only
- West Facing only |
1 x Exhaust Adaptor
1 x Dektite removed
1 x EW Roof frames
1 x NS Roof frames
(Wall duct and external insulated roof duct not incl.) |
Heating Duct and Vent |
The heated air is returned
to the building through this vent. It will vary from
building to building depending on your specific requirements. |
Built by your local installer,
plumber or builder.
Click here for further information |
External Roof Duct |
Suited for roofs
with no roof cavity and where ducting is exposed. Comes
with insulation and colorbond top hat for weatherproofing. |
Built by your local installer,
plumber or builder.
Click here for further information |
PV Frame
|
To tilt the PV panel to the
correct angle for maximum solar gain. |
Adjustable at various degrees
and heights. |